Three Phase 380V 4.0 ~75kW
FR300D series special purpose inverter for elevator, are developed for elevator, based on the core control arithmetic of FR300 vector control inverters, combined with the control requirements of elevator application.
Multi-stage S curve special for elevator
Flexibly start curve processing, multi-stage S curve setting, 4-level acce/dece time setting, which can make sure the comfortable of elevator.
Power Failure Self-help
DC 48V battery input or single phase 220V voltage input optional
Built-in brake unit, reduce the electrical system fittings cost.
Built-in brake unit is available for inverters with 75kw or lower power.
Full range of independent duct design, professional lightning protection design.
Featured with the function of motor parameters auto-tuning, static tuning or full-tuning.
Function of forced power failure self-help
and :
Model No. | Rated | Rated | Applicable motor | |
Input current | output current | kW HP | ||
A | A | |||
3-Phase:380V,50/60Hz Range:-15%~+30% | ||||
FR300D-4T-0.7B | 3,4 | 2,5 | 0,75 | 1 |
FR300D-4T-1.5B | 5 | 4,2 | 1,5 | 2 |
FR300D-4T-2.2B | 5,8 | 5,5 | 2,2 | 3 |
FR300D-4T-4.0B | 11 | 9,5 | 3.7、4 | 5 |
FR300D-4T-5.5B | 14,6 | 13 | 5,5 | 7,5 |
FR300D-4T-7.5B | 20,5 | 17 | 7,5 | 10 |
FR300D-4T-011B | 26 | 25 | 11 | 15 |
FR300D-4T-015B | 35 | 32 | 15 | 20 |
FR300D-4T-018B | 38,5 | 37 | 18,5 | 25 |
FR300D-4T-022B | 46,5 | 45 | 22 | 30 |
FR300D-4T-030B | 62 | 60 | 30 | 40 |
FR300D-4T-037B | 76 | 75 | 37 | 50 |
FR300D-4T-045B | 92 | 91 | 45 | 60 |
FR300D-4T-055B | 113 | 112 | 55 | 70 |
FR300D-4T-075B | 157 | 150 | 75 | 100 |